Examine This Report on Slip Resistance Inspection Services



ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6

When it pertains to guaranteeing security in commercial, commercial, and property spaces, slip resistance testing is a vital aspect. At ATTAR (Advanced Technology Testing & Research), we specialize in floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to help organizations and homeowner reduce threats and comply with safety standards.

With cutting edge devices such as the pendulum slip test maker and moisture meter for concrete, we supply precise and independent slip testing services throughout Australia. Our proficiency covers ASTM F2170 compliance, R Score evaluations, P Score tiles, and more, guaranteeing your floorings fulfill the greatest security standards.

 

 

Why Slip Resistance Testing is Necessary


Slips and falls are amongst the leading reasons for workplace and public injuries. Proper slip testing helps identify hazardous surfaces before accidents occur. Whether you need wet pendulum test evaluations or pendulum test for slip resistance, ATTAR delivers precise outcomes to boost security.

 

 

Secret Services Used by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Ranking and P Score tiles evaluations.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test using sophisticated moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent flooring failures.

3. Luminance Contrast Testing

- Ensures presence for aesthetically impaired people.
- Complies with Australian ease of access standards.

4. On-Site & Laboratory Testing

- Slip test machine for precise on-site examinations.
- Wet pendulum test for damp surface slip resistance.

 

 

Understanding Slip Resistance Ratings: R Ranking vs. P Ranking


When performing slip resistance testing, two key classifications are utilized:.

- R Ranking (Ramp Test - DIN 51130)
Steps slip resistance under lubricated conditions, typically used in Europe.

- P Ranking (Pendulum Test - AS 4586)
Evaluates dynamic friction utilizing a pendulum test slip resistance maker, commonly adopted in Australia.

ATTAR supplies independent slip testing to figure out whether your flooring meets the needed pendulum score tiles standards.

 

 

The Importance of Concrete Moisture Testing


Excess moisture in concrete slabs can cause flooring failures, mold growth, and adhesive destruction. Our concrete moisture testing services include:.

> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to guarantee optimal conditions for floor setups.

By discovering moisture issues early, we assist prevent costly repair work and ensure lasting flooring performance.

 

 

Luminance Contrast for Availability Compliance


Appropriate luminance contrast is vital for aesthetically impaired individuals to browse spaces securely. ATTAR evaluates:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile indications.

Our assessments make sure compliance with Australian Impairment Standards (AS 1428.1).

 

 

Why Choose ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where suitable).
> Advanced Testing Equipment (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Fast & Trusted Reporting.

For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

 

 

Typical Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping centres, dining establishments, and offices need safe flooring to prevent client and employee injuries. Our pendulum slip test guarantees compliance with security policies.

2. Industrial & Storage Facility Facilities

High-traffic industrial environments require durable, slip-resistant flooring. ATTAR's slip testing services assist maintain work environment security.

3. Healthcare & Aged Care Facilities

Health centers and assisted living home need to minimize slip dangers. Our luminance contrast and slip resistance testing make sure safe mobility for patients and personnel.

4. Public Infrastructure

Walkways, train stations, and federal government structures website require independent slip testing to satisfy availability and safety standards.

 

 

How ATTAR Performs Slip Resistance Testing


Action 1: Surface Assessment

We examine floor covering products and conditions (dry, wet, or contaminated).

Step 2: Pendulum Slip Test (AS 4663)

Using a slip test machine, we measure the dynamic coefficient of friction (DCOF).

Step 3: Wet Pendulum Test

Replicates slippery conditions to examine real-world slip threats.

Step 4: Reporting & Compliance Accreditation

Detailed reports with R Rating or P Rating tiles classifications.

 

 

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance technique involves a swinging arm with a rubber slider that imitates a foot's movement. The test steps:.

- Slip Prospective Value (SPV).
- Pendulum score tiles classification (P0 to P5).

Higher scores (P4/P5) suggest better slip resistance.

 

 

Moisture Testing for Concrete Floors: Preventing Failures


Moisture-related flooring failures can be expensive. ATTAR's concrete slab moisture testing includes:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete spot checks.
- Slab moisture test data analysis.

 

 

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's trusted provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast assessments. With cutting-edge technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and certified testing services.

Guarantee your residential or commercial property satisfies safety standards-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By choosing ATTAR, you invest in independent slip testing services, pendulum test slip resistance accuracy, and long-lasting floor security services. Let us help you create safer, certified, and moisture-resistant environments.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Comments on “Examine This Report on Slip Resistance Inspection Services”

Leave a Reply

Gravatar